All cool at Fukushima pool

Tepco workers have dealt with a temporary loss of cooling systems at Fukushima Daiichi unit 4's听used fuel pool. Meanwhile, Japan's first reactor to restart after the Fukushima accident has reached criticality.

Tepco workers have dealt with a temporary loss of cooling systems at Fukushima Daiichi unit 4's听used fuel pool. Meanwhile, Japan's first reactor to restart after the Fukushima accident has reached criticality.

Ohi (Kepco)
Ohi 3 back in action

The first Japanese nuclear power听reactor to be allowed to restart following the Fukushima accident, Ohi 3, has restarted and has now reached criticality, Kansai Electric has announced.

Alarms sounded at unit 4's fuel pool on the morning of Saturday 30 June, when a problem with the pool's alternative cooling system caused the system to shut down automatically.

After confirming that there was no leakage from the pool, Tokyo Electric Power Co (Tepco) investigations suggested that the problem lay in the system's uninterruptible power supply (UPS). After the problematic UPS was isolated, cooling was restarted in the afternoon of 1 July.

In total, the pool's cooling system was out of action for nearly 33 hours. During that time, the pool's temperature rose from 31掳C to 42.9掳C, well within its design parameters - the normal operating temperature of the听used fuel pond would be around 30掳C when circulation is maintained, although such pools are designed to be safe up to about 85掳C in the absence of pumped circulation.

At the time of the March 2011 earthquake and tsunami, Fukushima 4's pool was unusually full as it was being used to hold a full core load of 548 fuel assemblies while the reactor was undergoing maintenance, as well as used fuel assemblies. Work听was recently completed to install a protective steel cover over the pool, which was exposed by the hydrogen explosion that tore the roof off the building.